Bottom line: EV chargers are continuous loads, so the circuit is typically sized at 125% of the configured charging current. Always follow the charger manual and local code; have a licensed electrician verify the final breaker, wire, and settings.

Quick recommendation#

Decision pointRecommendation
Common breaker sizesA 32A charger commonly uses a 40A circuit, a 40A charger commonly uses a 50A circuit, and a 48A charger commonly uses a 60A circuit. The charger must be configured so its continuous output matches the circuit.
Why 125% mattersEV charging is treated as a continuous load because it can run for hours. That is why the circuit is larger than the charging current. A breaker is not a speed setting; it protects the circuit.
What to confirm in the quoteAsk the electrician to document breaker size, wire type and gauge, charger output setting, permit status, and whether any load-management equipment is required.

How to choose#

  • Start with the electrical panel and parking location before choosing a charger.
  • Match charger amperage to the circuit your electrician can safely install.
  • Use smart scheduling when your utility offers time-of-use or EV-specific rates.
  • Keep receipts, model numbers, permits, and installation records for rebates or tax paperwork.

Run the charger finder, compare current top picks, and get an installation quote that documents circuit size, charger output, permits, and any panel work. If the installation is expensive, compare a lower-amperage setting or load-management option before approving a panel upgrade.